[System] ;Specifies global configuration settings for the instrument. InstrumentName = NB551514 ;Indicates the name of the instrument. [Flowcell] ;Configuration items for flow cell objects. ActualXEdgeOfSlide = -0.0953 ; ActualYEdgeOfSlide = 0.0728 ; Flowcell1XOffset = 0 ; Flowcell1YOffset = 0 ; [PreRunChecks] ;Pre-run Checks SkipRequiredSoftwareCheck = False ;Skip the check for required software. SkipNetworkConnectionCheck = False ;Skip the check network connection check. SkipNetworkDiskSpaceCheck = False ;Skip the check for sufficient disk space at the Output Folder location. SkipInstrumentDiskSpaceCheck = False ;Skip the check for sufficient disk space at the Run Folder location. SkipConsumablesLoadedCheck = False ;Skip the check for all consumables properly loaded. SkipBitErrorRateCheck = False ;Skip the Bit Error Rate check. SkipZStepAndSettleCheck = False ;Skip the check for Z stage step-and-settle times. SkipWasteBottleFullCheck = False ;Skip the check for the waste bottle not being full. SkipDoorsClosedCheck = False ;Skip the check for all doors closed. SkipBsmCheck = False ;Skip the BSM check. SkipValveResponseCheck = False ;Skip the valve response check. SkipFluidicsInitializationCheck = False ;Skip the check for the fluidics system being properly initialized. SkipImagingLimitsCheck = False ;Skip the imaging limits check. SkipTemperatureCheck = False ;Skip the check for proper temperature ramping. SkipFlowCellRegistrationCheck = False ;Skip the flow cell registration test SkipClipCheck = True ;Skip the objective clip check SkipTempSensorsCheck = False ;Skip the temperature sensors check. SkipFanCheck = False ;Skip the fan check. SkipAutoCenterCheck = False ;Skip the auto center check. SkipVerifyInputFilesCheck = False ;Skip the verify input files check. [ImagingModule.CameraModule1] ;Settings for the read head. FocusCenterZMm = 0.01986797 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.002698919 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 3.5 ;Camera exposure time in ms RelativeCameraPositionXUm = 6.196976 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = 4.648209 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [ImagingModule.CameraModule2] ;Settings for the read head. FocusCenterZMm = 0.0234118 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.003025455 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 4.4 ;Camera exposure time in ms RelativeCameraPositionXUm = 0 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = 0 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [ImagingModule.CameraModule3] ;Settings for the read head. FocusCenterZMm = 0.03311074 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.002836823 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 3.8 ;Camera exposure time in ms RelativeCameraPositionXUm = 11.61957 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = -1.549721 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [ImagingModule.CameraModule4] ;Settings for the read head. FocusCenterZMm = 0.02466167 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.002584703 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 3.9 ;Camera exposure time in ms RelativeCameraPositionXUm = -3.873348 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = -9.295464 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [ImagingModule.CameraModule5] ;Settings for the read head. FocusCenterZMm = 0.02513162 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.00251026 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 4.7 ;Camera exposure time in ms RelativeCameraPositionXUm = 12.39443 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = -4.648209 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [ImagingModule.CameraModule6] ;Settings for the read head. FocusCenterZMm = -0.009254307 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.002449884 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 3.8 ;Camera exposure time in ms RelativeCameraPositionXUm = 3.872871 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = 3.098488 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [Fluidics.FlowCellFluidics1.IxFlowCellTemp] ;Settings for the temp controller. TemperatureOffset = 0 ;Set the offset between the readback and flowcell. CalibrationLowTarget = 0 ;The temperature which is the set point for the low temperature calibration point. CalibrationLowMeasured = 0 ;The temperature the technician measured at the low temperature point during the calibration procedure. CalibrationHighTarget = 0 ;The temperature which is the set point for the high temperature calibration point. CalibrationHighMeasured = 0 ;The temperature the technician measured at the high temperature point during the calibration procedure. [Fluidics.FlowCellFluidics1.IxPressureSensor1] ;Settings for the pressure sensor. Gain = 67.82 ;Standard transducer calibration. Intercept = -19.2 ;Approximate intercept to be set at manufacturing. [Fluidics.FlowCellFluidics1.IxPressureSensor2] ;Settings for the pressure sensor. Gain = 67.82 ;Standard transducer calibration. Intercept = -19.2 ;Approximate intercept to be set at manufacturing.