ATAqC

Sample Information

Sample 151210_MONK_0462_AC8C29ACXX_L4_GGACTCCT_1_pf.PE2SE
Genome hg19
Paired/Single-ended Paired-ended
Read length 101

Summary

Read count from sequencer 64,334,676
Read count successfully aligned 62,513,930
Read count after filtering for mapping quality 54,139,986
Read count after removing duplicate reads 53,072,713
Read count after removing mitochondrial reads (final read count) 51,929,944
Note that all these read counts are determined using 'samtools view' - as such,
these are all reads found in the file, whether one end of a pair or a single 
end read. In other words, if your file is paired end, then you should divide 
these counts by two. Each step follows the previous step; for example, the 
duplicate reads were removed after reads were removed for low mapping quality.
This bar chart also shows the filtering process and where the reads were lost
over the process. Note that each step is sequential - as such, there may
have been more mitochondrial reads which were already filtered because of
high duplication or low mapping quality. Note that all these read counts are 
determined using 'samtools view' - as such, these are all reads found in 
the file, whether one end of a pair or a single end read. In other words, 
if your file is paired end, then you should divide these counts by two.

Alignment statistics

Bowtie alignment log

32167338 reads; of these:
  32167338 (100.00%) were paired; of these:
    1097785 (3.41%) aligned concordantly 0 times
    24108321 (74.95%) aligned concordantly exactly 1 time
    6961232 (21.64%) aligned concordantly >1 times
    ----
    1097785 pairs aligned concordantly 0 times; of these:
      67110 (6.11%) aligned discordantly 1 time
    ----
    1030675 pairs aligned 0 times concordantly or discordantly; of these:
      2061350 mates make up the pairs; of these:
        1820746 (88.33%) aligned 0 times
        152134 (7.38%) aligned exactly 1 time
        88470 (4.29%) aligned >1 times
97.17% overall alignment rate

  

Samtools flagstat

64334676 + 0 in total (QC-passed reads + QC-failed reads)
0 + 0 secondary
0 + 0 supplementary
0 + 0 duplicates
62513930 + 0 mapped (97.17%:-nan%)
64334676 + 0 paired in sequencing
32167338 + 0 read1
32167338 + 0 read2
62139106 + 0 properly paired (96.59%:-nan%)
62304852 + 0 with itself and mate mapped
209078 + 0 singletons (0.32%:-nan%)
22842 + 0 with mate mapped to a different chr
7309 + 0 with mate mapped to a different chr (mapQ>=5)

  

Filtering statistics

Mapping quality > q30 (out of total) 54,139,986 0.842
Duplicates (after filtering) 1,067,273.0 0.039
Mitochondrial reads (out of total) 2,527,865 0.040
Final reads (after all filters) 51,929,944 0.807
Mapping quality refers to the quality of the read being aligned to that 
particular location in the genome. A standard quality score is > 30. 
Duplications are often due to PCR duplication rather than two unique reads
mapping to the same location. High duplication is an indication of poor 
libraries. Mitochondrial reads are often high in chromatin accessibility
assays because the mitochondrial genome is very open. A high mitochondrial
fraction is an indication of poor libraries. Based on prior experience, a
final read fraction above 0.70 is a good library.
  

Library complexity statistics

ENCODE library complexity metrics

Metric Result
NRF 0.946665281363 - OK
PBC1 0.973913388181 - OK
PBC2 47.3936197691 - OK
The non-redundant fraction (NRF) is the fraction of non-redundant mapped reads 
in a dataset; it is the ratio between the number of positions in the genome 
that uniquely mapped reads map to and the total number of uniquely mappable 
reads. The NRF should be > 0.8. The PBC1 is the ratio of genomic locations
with EXACTLY one read pair over the genomic locations with AT LEAST one read 
pair. PBC1 is the primary measure, and the PBC1 should be close to 1. 
Provisionally 0-0.5 is severe bottlenecking, 0.5-0.8 is moderate bottlenecking, 
0.8-0.9 is mild bottlenecking, and 0.9-1.0 is no bottlenecking. The PBC2 is 
the ratio of genomic locations with EXACTLY one read pair over the genomic 
locations with EXACTLY two read pairs. The PBC2 should be significantly 
greater than 1.

Picard EstimateLibraryComplexity

591,469,370

Yield prediction

Preseq performs a yield prediction by subsampling the reads, calculating the
number of distinct reads, and then extrapolating out to see where the 
expected number of distinct reads no longer increases. The confidence interval
gives a gauge as to the validity of the yield predictions.

Fragment length statistics

Metric Result
Fraction of reads in NFR 0.621869018036 - OK
NFR / mono-nuc reads 3.98085478773 - OK
Presence of NFR peak OK
Presence of Mono-Nuc peak OK
Presence of Di-Nuc peak OK
Open chromatin assays show distinct fragment length enrichments, as the cut 
sites are only in open chromatin and not in nucleosomes. As such, peaks 
representing different n-nucleosomal (ex mono-nucleosomal, di-nucleosomal) 
fragment lengths will arise. Good libraries will show these peaks in a 
fragment length distribution and will show specific peak ratios.

Sequence quality metrics

GC bias

Open chromatin assays are known to have significant GC bias. Please take this
into consideration as necessary.

Annotation-based quality metrics

Enrichment plots (TSS)

Open chromatin assays should show enrichment in open chromatin sites, such as
TSS's. An average TSS enrichment is above 6-7. A strong TSS enrichment is 
above 10.
  

Annotated genomic region enrichments

Fraction of reads in universal DHS regions 10,941,216 0.213
Fraction of reads in blacklist regions 179,249 0.003
Fraction of reads in promoter regions 2,895,522 0.056
Fraction of reads in enhancer regions 14,886,707 0.290
Fraction of reads in called peak regions 7,293,651 0.142
Signal to noise can be assessed by considering whether reads are falling into
known open regions (such as DHS regions) or not. A high fraction of reads 
should fall into the universal (across cell type) DHS set. A small fraction
should fall into the blacklist regions. A high set (though not all) should
fall into the promoter regions. A high set (though not all) should fall into 
the enhancer regions. The promoter regions should not take up all reads, as
it is known that there is a bias for promoters in open chromatin assays.

Comparison to Roadmap DNase

This bar chart shows the correlation between the Roadmap DNase samples to
your sample, when the signal in the universal DNase peak region sets are 
compared. The closer the sample is in signal distribution in the regions
to your sample, the higher the correlation.